YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication

    • YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication
    • YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication
  • YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication

    Product Details:

    Place of Origin: China/Japan
    Brand Name: YOKOGAWA
    Certification: CE/MC
    Model Number: AXF100G-NNCE1N-AA11-0NB

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: US$2295/set
    Packaging Details: carton
    Delivery Time: 6-8 weeks
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 1000set/month
    Contact Now
    Detailed Product Description
    Lining: Ceramics Size: DN100
    Type: Tube+converter Communication: Brain

    Totalizer Display Function (*2):
    The flow rate is counted one pulse at a time according to the setting of totalization pulse weights. For forward and reverse flow measurement functions, the totalized values of the flow direction (forward or reverse) and the flow direction are displayed on the indicator together with the units. The difference of totalized values between the forward and reverse flow rate can be displayed.
    Totalization for the reverse flow rate is carried out only when “Forward and reverse flow measurement func- tions” is selected.
    Damping Time Constant (*2):
    Time constant can be set from 0.1 second to 200.0 seconds (63% response). The default is 3 seconds.
    Span Setting Function (*2):
    Span flows can be set in units such as volume flow rate, mass flow rate, time, or flow rate value. The velocity unit can also be set.
    Volume Flow Rate Unit: kcf, cf, mcf, Mgal (US), kgal (US), gal (US), mgal (US), kbbl (US)*, bbl (US)*, mbbl (US)*, bbl (US)*, Ml (megaliter), m3, kl (kiloliter), l (liter), cm3
    Mass Flow Rate Unit (Density must be set.): klb (US), lb (US), t (ton), kg, g
    Velocity Unit: ft, m (meter)
    Time Unit: s (sec), min, h (hour), d (day)
    * “US oil” or “US Beer” can be selected.
    Pulse Output (*1)(*2):
    Scaled pulse can be output by setting a pulse weight. Pulse Width: Duty 50% or fixed pulse width (0.05, 0.1,
    0.5, 1, 20, 33, 50, 100 ms) can be selected.
    Output Rate: 0.0001 to 10,000 pps (pulse/second)
    Multi-range Function (*1)(*2):
    •Range switching via status input
    Status input enables the switching of up to two ranges.
    •Automatic range switching
    When the flow rate exceeds 100 % of the range, transition to the next range (up to four ranges) is carried out automatically. Range switching can be confirmed by status outputs and indicator.
    Forward and Reverse Flow Measurement Functions (*1)(*2): Flows in both forward and reverse directions can be measured. The reverse flow measurement can be confirmed by status output and indicator.
    Totalization Switch (*1)(*2):
    The status output is carried out when a totalized value becomes equal to or greater than the set value.

     


    Preset Totalization (*1)(*2):
    The parameter setting or status input enables a totalized value to be preset to a setting value or zero.
    0% Signal Lock (*1)(*2):
    Status input forcibly fixes the instantaneous flow rate display, current output, pulse output, and flow rate totalization to 0%.
    Alarm Selection Function (*2):
    Alarms are classified into the System Alarms (hard failures), Process Alarms (such as ‘Empty Pipe’, ‘Signal Overflow’ and ‘Adhesion Alarm’), Setting Alarms, and Warnings.
    Whether alarms should be generated or not can be selected for each item.
    The current output generated for an alarm can be selected from among 2.4 mA or less, fixed to 4 mA, 21.6 mA or more, or HOLD.
    Alarm Output (*1)(*2):
    Alarms are generated only for the items selected via the ‘Alarm Selection Function’ if relevant failures occur.
    Self Diagnostics Functions (*2):
    If alarms are generated, details of the System Alarms, Process Alarms, Setting Alarms and Warnings are displayed together with concrete descriptions of countermeasures.
    Flow Upper/Lower Limit Alarms (*1)(*2):
    If a flow rate becomes greater or smaller than the set value, this alarm is generated. In addition, two upper limits (H, HH) and two lower limits (L, LL) can be set.
    If a flow rate becomes greater or smaller than any of the set values, the status is output.
    Electrode Adhesion Diagnostics Function (*1) (*2): This function enables monitoring of the adhesion level of insulating substances to the electrodes. Depending on the status of adhesion, users are notified by a warning or an alarm via status outputs. If replaceable electrodes are used, they can be removed and cleaned when adhesion occurs.

     

     

    AXF standard:

     

    Use Process Connection Available Size Lining Electrode Material

     

    General- Purpose Use

     

    Wafer

    25 to 300 mm

    (1.0 to 12 in.)

     

    PFA/

    Polyurethane Rubber

    JIS SUS316L (AISI 316L SS/EN 1.4404

    equivalent)(*1)

     

    Flange

    25 to 400 mm

    (1.0 to 16 in.)

     

     

     

    Replacement model for earlier ADMAG or ADMAG AE

    Use Process Connection Available Size Lining Electrode Material

     

    General- Purpose Use

     

     

    Flange

     

    150 to 250 mm

    (6.0 to 10 in.)

     

    PFA/

    Polyurethane Rubber

    JIS SUS316L (AISI 316L SS/EN 1.4404

    equivalent)(*1)

     

    YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication

    YOKOGAWA magnetic flowtube AXF100G-NNCE1N-AA11-0NB wafer converter AXFG11 Brain communication