Sales & Support:
Home ProductsYOKOGAWA EJA transmitters

Beijing Usin Technology Co.,Ltd

YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA

    • YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA
    • YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA
    • YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA
  • YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA

    Product Details:

    Place of Origin: China/Japan
    Brand Name: YOKOGAWA
    Certification: IEC61508,CE
    Model Number: EJA120A-DES0A-20DN

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: $425/set
    Packaging Details: carton
    Delivery Time: 2-4weeks
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 1000 set/Month
    Contact Now
    Detailed Product Description
    Output: 4-20mA Delivery Time: 2 Weeks
    Safety: IEC61508 Display: Digital Indicator
    Communication: HART

    The high performance gauge pressure transmitter model EJA430A can be used to measure liquid, gas, or steam pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured gauge pressure.
    Model EJA430A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or µXL™ or HART® 275 host.
     
     
    External Zero Adjustment “Q”
    External zero is continuously adjustable with 0.01 % incremental resolution of span. Span may be adjusted locally using the digital indicator with range switch.
    Mounting Position Effect
    Rotation in diaphragm plane has no effect. Tilting up to 90 ° will cause zero shift up to 0.4 kPa {1.6 inH2O} which can be corrected by the zero adjustment.
    Output “Q”
    Two wire 4 to 20 mA DC output with digital communi- cations. BRAIN or HART FSK protocol are superim- posed on the 4 to 20 mA signal.
    Failure Alarm
    Output status at CPU failure and hardware error;
    Up-scale: 110%, 21.6 mA DC or more(standard) Down-scale: -5%, 3.2 mA DC or less
    -2.5%, 3.6 mA DC or less (Optional code /F1)
    Note: Applicable for Output signal code D and E
    Damping Time Constant (1st order)
    The sum of the amplifier and capsule damping time constant must be used for the overall time constant. Amp damping time constant is adjustable from 0.2 to 64 seconds.
     
     
    < Ordering Information > “Q”
    Specify the following when ordering
    1.Model, suffix codes, and optional codes
    2.Calibration range and units:
    1)Calibration range can be specified with range value specifications up to 5 digits
    (excluding any decimal point) for low or high range limits within the range of -32000 to 32000.
    2)Specify only one unit from the table, ‘Settings when shipped.’
    3.Select linear or square root for output mode and display mode.
    Note: If not specified, the instrument is shipped set for linear mode.
    4.
    Select normal or reverse for operation mode
    Note: If not specified, the instrument is shipped in normal operation mode.
    5.Display scale and units (for transmitters equipped with integral indicator only)
    Specify either 0 to 100 % or engineering unit scale and ‘Range and Unit’ for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of
    -19999 to 19999.
    6.Tag Number (if required)
     
     
    ■SELECTION GUIDE

     

    Application Type

     

    Model

     

    Capsule

    Measurement Span Maximum Working Pressure
            kPa inH2O MPa psi

     

    Differential Pressure

     

    Traditional-Mounting*1

     

    EJA110A

    L M H V 0.5 to 10 1 to 100 5 to 500

    2 to 40

    4 to 400

    20 to 2000

    16*4

    16

    16

    2250*4

    2250

    2250

            0.14 to 14MPa 20 to 2000 psi 16 2250

     

    Flow

     

    Integral Orifice

     

    EJA115

    L M H 1 to 10 4 to 40 3.5 500
            2 to 100 8 to 400 14 2000
            20 to 210 80 to 830 14 2000

    Differential Pressure & Liquid Level

    with Remote Seals

    Extended Flush Combination EJA118N EJA118W EJA118Y M H 2.5 to 100 25 to 500

    10 to 400

    100 to 2000

     

    Based on Flange Rating

    Draft Range Traditional-Mounting*1 EJA120A E 0.1 to 1 0.4 to 4 50 kPa 7.25
    Differential Pressure & Liquid Level Traditional-Mounting*1 EJA130A M H

    1 to 100

    5 to 500

    4 to 400

    20 to 2000

    32

    32

    4500

    4500

    Liquid Level, Closed or Open Tank Flush Extended EJA210A EJA220A M H

    1 to 100

    5 to 500

    4 to 400

    20 to 2000

    Based on Flange Rating
    Absolute (vacuum) Pressure

     

    Traditional-Mounting*1

     

    EJA310A

    L M A

    0.67 to 10*2 1.3 to 130*2

    0.03 to 3 MPa*2

    2.67 to 40*2

    0.38 to 38 inHg*2

    4.3 to 430 psi*2

    10 kPa*2

    130 kPa*2

    3000 kPa*2

    40 in H2O*2

    18.65*2

    430*2

    Gauge Pressure Traditional-Mounting*1 EJA430A A B

    0.03 to 3 MPa

    0.14 to 14 MPa

    4.3 to 430 psi 20 to 2000 psi

    3

    14

    430

    2000

    Gauge Pressure with Remote Seal Extended EJA438N A B

    0.06 to 3 MPa

    0.46 to 7 MPa

    8.6 to 430 psi 66 to 1000 psi Based on Flange Rating
    Gauge Pressure with Remote Seal Flush EJA438W A B

    0.06 to 3 MPa

    0.46 to 14 MPa

    8.6 to 430 psi 66 to 2000 psi Based on Flange Rating
    High Gauge Traditional-Mounting*1 EJA440A C D

    5 to 32 MPa

    5 to 50 MPa

    720 to 4500 psi

    720 to 7200 psi

    32

    50

    4500

    7200

     

    Absolute & Gauge Pressure*3

     

    Direct-Mounting

    EJA510A EJA530A A B C D

    10 to 200

    0.1 to 2 MPa

    0.5 to 10 MPa 5 to 50 MPa

    1.45 to 29 psi

    14.5 to 290 psi

    72.5 to 1450 psi 720 to 7200 psi

    200 kPa

    2

    10

    50

    29

    290

    1450

    7200

     

     

     

    YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA

    YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA

    YOKOGAWA EJA430A Gauge Pressure Transmitter EJA430A-EAS5A-92DN HART protocol 4-20mA

    Contact Details
    Beijing Usin Technology Co.,Ltd

    Send your inquiry directly to us (0 / 3000)