Sales & Support:
Home ProductsYOKOGAWA EJA transmitters

Beijing Usin Technology Co.,Ltd

YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS protocol PA

    • YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA
    • YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA
    • YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA
  • YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA

    Product Details:

    Place of Origin: China Japan
    Brand Name: YOKOGAWA
    Certification: IEC61508,CE
    Model Number: EJA310A-GMS5A-92DN

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: $955/set
    Packaging Details: carton
    Delivery Time: 4-8weeks
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 1000 set/Month
    Contact Now
    Detailed Product Description
    Safty Standard: IEC61508 Measuring Range: 1.3 To 130 KPa {13 To 1300 Mbar}
    Communication: PROFIBUS PA Protocol Product Name: Absolute Pressure Transmitter

    The high performance gauge pressure transmitter model EJA310A can be used to measure liquid, gas, or steam pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured absolute pressure.
    Model EJA310A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM-CS™ or µXL™ or HART® 275 host.
    STANDARD SPECIFICATIONS
    Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “Q.”
    ☐ PERFORMANCE SPECIFICATIONS
    Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil.
    Reference Accuracy of Calibrated Span
    (including the effects of zero-based linearity, hyster- esis, and repeatability)
    0.15 % of Span or
    0.20 % of Span for L Capsule
    0.075 % of Span when /HAC is specified.
    For spans below X,
    X
    ±[0.1 + 0.05 Span ] % of Span or
    X
    ±[0.15 + 0.05 Span ] % of Span for the L Capsule
    X
    ±[0.025 + 0.05 Span ] % of Span when/HAC is specified.
    where X equals:
    Capsule X kPa {psi}
    L 5.4 {22 inH2O}
    M 21.8 {3.2}
    A 250 {36}
    Ambient Temperature Effects
    Total Effects per 28 ˚C (50 ˚F) Change
    Capsule Effect
    L ±[0.095 % Span + 0.118 % URL]
    M ±[0.084 % Span + 0.028 % URL]
    A ±[0.080 % Span + 0.008 % URL]
    Stability
    ±0.1 % of URL per 12 months
    Power Supply Effects “Q”
    ±0.005 % per Volt (from 21.6 to 32 V DC, 350 K)
     
     
    FUNCTIONAL SPECIFICATIONS
    Span & Range Limits
    (Units are in absolute terms.)
    T01E.EPS
    URL is defined as the Upper Range Limit from the table above.
    Minimum Input Pressure at Calibration
    L capsule: 130 Pa abs. {1 mmHg abs.}
    M and A capsules: 2.7 kPa abs. {20 mmHg abs.}
    At range calibrating testing, minimum input pressure of 130 Pa abs. {1 mmHg abs.} is obtained by selecting Optional code S1. Always select S1 for M capsule with higher range value(HRV) not exceeding
    3.4 kPa abs. {25 mmHg abs.}
    Zero Adjustment Limits
    Zero can be fully elevated or suppressed, within the Lower and Upper Range Limits of the capsule.
    External Zero Adjustment “Q”
    External zero is continuously adjustable with 0.01 % incremental resolution of span. Span may be adjusted locally using the digital indicator with range switch.
    Mounting Position Effect
    Rotation in diaphragm plane has no effect. Tilting up to 90 ˚ will cause zero shift up to 0.4 kPa {1.6 inH2O}
    which can be corrected by the zero adjustment.
     

    Output “Q”
    Two wire 4 to 20 mA DC output with digital communi- cations. BRAIN or HART FSK protocol are superim- posed on the 4 to 20 mA signal.
    Failure Alarm
    Output status at CPU failure and hardware error;
    Up-scale: 110%, 21.6 mA DC or more(standard) Down-scale: -5%, 3.2 mA DC or less
    -2.5%, 3.6 mA DC or less (Optional code /F1)
    Note: Applicable for Output signal code D and E
    Damping Time Constant (1st order)
    The sum of the amplifier and capsule damping time constant must be used for the overall time constant.
    Amp damping time constant is adjustable from 0.2 to 64 seconds.


    PHYSICAL SPECIFICATIONS
    Wetted Parts Materials Diaphragm
    Hastelloy C-276
    Cover flange
    SCS14A
    Process connector
    SCS14A
    Capsule Gasket
    Teflon-coated SUS316L
    Vent and Drain Plug
    SUS316 or ASTM grade 316
    Process Connector Gasket
    PTFE Teflon
    Fluorinated rubber for Optional code /N2 and /N3
    Non-wetted Parts Materials Bolting

     

     

    The high performance gauge pressure transmitter model EJA310A can be used to measure liquid, gas, or steam pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured absolute pressure.
    Model EJA310A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM-CS™ or µXL™ or HART® 275 host.
    ■ STANDARD SPECIFICATIONS
    Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “Q.”
    ☐ PERFORMANCE SPECIFICATIONS
    Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil.
    Reference Accuracy of Calibrated Span
    (including the effects of zero-based linearity, hyster- esis, and repeatability)
    0.15 % of Span or
    0.20 % of Span for L Capsule
    0.075 % of Span when /HAC is specified.
    For spans below X,
    X
    ±[0.1 + 0.05 Span ] % of Span or
    X
    ±[0.15 + 0.05 Span ] % of Span for the L Capsule
    X
    ±[0.025 + 0.05 Span ] % of Span when/HAC is specified.
    where X equals:
    Capsule X kPa {psi}
    L 5.4 {22 inH2O}
    M 21.8 {3.2}
    A 250 {36}
    Ambient Temperature Effects
    Total Effects per 28 ˚C (50 ˚F) Change
    Capsule Effect
    L ±[0.095 % Span + 0.118 % URL]
    M ±[0.084 % Span + 0.028 % URL]
    A ±[0.080 % Span + 0.008 % URL]
    Stability
    ±0.1 % of URL per 12 months
    Power Supply Effects “Q”
    ±0.005 % per Volt (from 21.6 to 32 V DC, 350 K)
    As specified in order *1
    Output Mode ‘Linear’
    Display Mode ‘Linear’
    Operation Mode ‘Normal’ unless otherwise specified in order
    Damping Time Constant ‘2 sec.’
    Calibration Range Lower Range Value As specified in order
    Calibration Range Higher Range Value As specified in order
    Calibration Range Units

    Selected from mmH2O abs, mmHg abs, Torr, Pa abs, hPa abs, kPa abs, MPa abs, mbar abs, bar abs, kgf/cm2 abs, inH2O abs, inHg abs, ftH2O abs, psia, psi abs, or atm. (Only one unit can be specified)

     

     

     

    The high performance gauge pressure transmitter model EJA310A can be used to measure liquid, gas, or steam pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured absolute pressure.
    Model EJA310A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM-CS™ or µXL™ or HART® 275 host.
    ■ STANDARD SPECIFICATIONS
    Refer to GS 01C22T02-00E for FOUNDATION Fieldbus communication type and GS 01C22T03-00E for PROFIBUS PA communication type marked with “Q.”
    ☐ PERFORMANCE SPECIFICATIONS
    Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil.
    Reference Accuracy of Calibrated Span
    (including the effects of zero-based linearity, hyster- esis, and repeatability)
    0.15 % of Span or
    0.20 % of Span for L Capsule
    0.075 % of Span when /HAC is specified.
    For spans below X,
    X
    ±[0.1 + 0.05 Span ] % of Span or
    X
    ±[0.15 + 0.05 Span ] % of Span for the L Capsule
    X
    ±[0.025 + 0.05 Span ] % of Span when/HAC is specified.
    where X equals:
    Capsule X kPa {psi}
    L 5.4 {22 inH2O}
    M 21.8 {3.2}
    A 250 {36}
    Ambient Temperature Effects
    Total Effects per 28 ˚C (50 ˚F) Change
    Capsule Effect
    L ±[0.095 % Span + 0.118 % URL]
    M ±[0.084 % Span + 0.028 % URL]
    A ±[0.080 % Span + 0.008 % URL]
    Stability
    ±0.1 % of URL per 12 months
    Power Supply Effects “Q”
    ±0.005 % per Volt (from 21.6 to 32 V DC, 350 K)
    Description
    Factory Mutual (FM) FM Explosionproof Approval *1 *3 *4
    Applicable standard: FM3600, FM3615, FM3810, ANSI/NEMA250 Explosionproof for Class I, Division 1, Groups B, C and D
    Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Hazardous (classified) locations, indoors and outdoors (NEMA 4X) Temperature class: T6
    Amb. Temp.: –40 to 60°C (–40 to 140°F)
    FM Intrinsically safe Approval *1 *3 *4
    Applicable standard: FM3600, FM3610, FM3611, FM3810, ANSI/NEMA250 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1 Hazardous Locations.
    Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2, Groups E, F & G, and Class III, Division 1 Hazardous Locations.
    Enclosure: “NEMA 4X”, Temp. Class: T4, Amb. Temp.: –40 to 60°C (–40 to 140°F)
    Intrinsically Safe Apparatus Parameters
    [Groups A, B, C, D, E, F and G]
    Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 µH
    [Groups C, D, E, F and G]
    Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 µH
    Combined FF1 and FS1 *1 *3 *4
    ATEX ATEX Flameproof Approval *2 *4
    Applicable standard: EN 60079-0, EN 60079-1 Certificate: KEMA 02ATEX2148
    II 2G Ex d IIC T4, T5, T6
    Amb. Temp.: T5; –40 to 80°C ( –40 to 176°F), T4 and T6; –40 to 75°C ( –40 to 167°F) Max. process Temp.: T4; 120°C (248°F), T5; 100°C (212°F), T6; 85°C (185°F)
    ATEX Intrinsically safe Approval *2 *3 *4
    Applicable standard: EN50014, EN50020, EN50284 Certificate: KEMA 02ATEX1030X
    II 1G EEx ia IIC T4, Amb. Temp.: –40 to 60°C (–40 to 140°F) Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 µH

     

     

     

     

    YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA

    YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA

    YOKOGAWA EJA310A Absolute Pressure Transmitter EJA310A-GMS5A-92DN PROFIBUS  protocol PA

    Contact Details
    Beijing Usin Technology Co.,Ltd

    Send your inquiry directly to us (0 / 3000)